Railway signalling cable, unscreened, armoured

Railway Signalling and Telecommunications Cables

Safety and control cable for fixed installation in railway installations. The cables must be protected from the constant influence of sunlight.

Design

This product consists of:

  • 1
    Copper conductor, round solid (RE)
  • 2
    Core insulation (PE), cores star quaded and quads stranded in layers
  • 3
    Inner covering (plastic foil)
  • 4
    Inner sheath (PE, black)
  • 5
    Armouring (bare steel tape, wrapped with plastic tape)
  • 6
    Sheath (PVC grey RAL 7035)

Technical Data

Standard: ÖVE-K 11
Rated Voltage: max. 250 V
Bending radius (min.): 12 x Ø of cable
Fire properties: EN 60332-1-2: flame retardant
Core identification: Colour code with trace quad in each layer
Temperature range: 
  • Laying temperature: min. -5°C
  • Operating temperature: -30°C up to 60°C
  • Conductor temperature: max. 80°C
Cable image - S-2Y2YBY quad
+
-
Cable image - S-2Y2YBY quad
+
-
Cable image - S-2Y2YBY quad
+
-

Contact us

Are you interested in this product?

Ing. Štěpán Laštůvka

Product supervisor

+420 732 912 682
[email protected]

Options

Add to inquiry
Number of quads x conductor diameter
Standard lengths/packing (m)
Outer diameter appr. (mm)
Total weight appr. (kg/km)
1 x 4 x 0.8
500 D, 1000 D
14.0
204
2 x 4 x 0.8
500 D, 1000 D
18.0
335
3 x 4 x 0.8
500 D, 1000 D
18.0
374
5 x 4 x 0.8
500 D, 1000 D
21.0
464
7 x 4 x 0.8
500 D, 1000 D
22.0
540
10 x 4 x 0.8
500 D, 1000 D
27.0
750
15 x 4 x 0.8
500 D, 1000 D
30.0
975
20 x 4 x 0.8
500 D, 1000 D
33.0
1174
25 x 4 x 0.8
500 D, 1000 D
37.0
1438
1 x 4 x 0.9
500 D, 1000 D
15.0
236
2 x 4 x 0.9
500 D, 1000 D
20.0
382
3 x 4 x 0.9
500 D, 1000 D
20.0
419
5 x 4 x 0.9
500 D, 1000 D
23.0
542
7 x 4 x 0.9
500 D, 1000 D
25.0
681
10 x 4 x 0.9
500 D, 1000 D
29.0
895
15 x 4 x 0.9
500 D, 1000 D
33.0
1168
20 x 4 x 0.9
500 D, 1000 D
38.0
1485
25 x 4 x 0.9
500 D, 1000 D
41.0
1736
1 x 4 x 1.4
500 D, 1000 D
17.0
336
2 x 4 x 1.4
500 D, 1000 D
25.0
635
3 x 4 x 1.4
500 D, 1000 D
26.0
718
5 x 4 x 1.4
500 D, 1000 D
31.0
998
7 x 4 x 1.4
500 D, 1000 D
33.0
1197
10 x 4 x 1.4
500 D, 1000 D
40.0
1679
15 x 4 x 1.4
500 D, 1000 D
47.0
2327
20 x 4 x 1.4
500 D, 1000 D
52.0
2859
25 x 4 x 1.4
500 D, 1000 D
58.0
3577
1 x 4 x 1.8
500 D, 1000 D
20.0
447
2 x 4 x 1.8
500 D, 1000 D
30.0
880
3 x 4 x 1.8
500 D, 1000 D
31.0
1020
5 x 4 x 1.8
500 D, 1000 D
37.0
1454
7 x 4 x 1.8
500 D, 1000 D
40.0
1767
10 x 4 x 1.8
500 D, 1000 D
49.0
2527
15 x 4 x 1.8
500 D, 1000 D
57.0
3534
20 x 4 x 1.8
500 D, 1000 D
65.0
4470

Technical changes reserved.

All figures are therefore without guarantee.

To inquiry

Check other recommended products by SKB Group

Railway Signalling and Telecommunications Cables

Browse products
Railway Signalling and Telecommunications Cables
Earthing and Short Circuiting Cables and Bare Wires
Instalation and Harmonised Cables and Wires
Low Voltage Cables 0,6/1 kV
Safety Cables with circuit integrity
Medium Voltage Cables up to 36 kV
Rubber, Silicone and PUR Cables
Commercial Vehicles and EVC Cables
Automation and Motor Supply Cables
Special Cables

Our Code of Conduct and its associated regulations are not seeking to „invent“ new approaches. Instead, they aim to clearly demonstrate the obligations we must fulfill nowadays.

Let's work
together

SKB

SKB Group

SKB Group

SKB Industrieholding GmbH

Himberger Strasse 50, 2320 Schwechat, Österreich

  • +43 1 70170-0

  • [email protected]

  • Impressum

  • Contact

All rights reserved. Copyright © 2026