SHKFH-R B2ca s1a d1 a1
FRNC low-frequency communication cables, shielded, UV resistant, Water resistant
The cables are designed for the transmission of analogue and digital data, to places with a higher risk of fire and a large concentration of people, where there is no requirement to maintain the functionality of the entire cable installation in the event of fire. In case of fire, the cable releases a small amount of heat and smoke. The cables are UV-resistant and water resistant AD1 - AD7
Design
This product consists of:
1
Copper conductor, round solid (RE)
2
Core insulation (halogen-free polymer compound), cores stranded to pair
3
Inner covering (dielectric, separating tape)
4
Screen (plastic laminated aluminium tape with CuSn drainwire)
5
Inner covering (halogen-free filling compound)
6
Sheath (halogen-free polymer compound, orange, UV resistant, water resistant)
Technical Data
Standard:TP PRAKAB 05/01
Certificate:
EZÚ Czech Republic
TSÚS Slovakia
Test Voltage:
core/core 1,5 kV / 50 Hz
core/screen 1 kV / 50 Hz
Rated Voltage:100 V
Bending radius (min.):
10 x Ø of cable up to 20 mm
12 x Ø of cable from 20 mm to 40 mm
15 x Ø of cable over 40 mm
Fire properties:
ČSN EN 60332-1-2: self-extinguishing
ČSN EN 60754-2: halogen-free, non-corrosive combustion gases