SKB
Prakab
SKW
ICS
KONEKA
IKK

Menu

  • Impressum
  • Contact
  • Whistleblowing
  • Download Center
  • Products
  • Videos
SKB Group logo

Metal
Prices

Cu
SKB-Group
Validity: 06.11.2025
Cu
Quotation
€ / 100 kg:962.01
SKW
Validity: 07.11.2025
Cu
Quotation€ / 100 kg:1,005.23
Surcharge€ / 100 kg:875.23
Prakab (Czech Market)
Validity: CW 45/2025
Cu
Quotation
Kč / kg:190.31
Prakab (Slovak Market)
Validity: CW 45/2025
Cu
Quotation
€ / kg:7.87

All statements without guarantee.

Al
SKB-Group
Validity: 06.11.2025
Al
Quotation
€ / 100 kg:363.18
SKW
Validity: 07.11.2025
Al
Quotation€ / 100 kg:412.05
Surcharge€ / 100 kg:312.05
Prakab (Czech Market)
Validity: CW 45/2025
Al
Quotation
Kč / kg:54.42
Prakab (Slovak Market)
Validity: CW 45/2025
Al
Quotation
Kč / kg:54.42

All statements without guarantee.

Cables

(N)HXCH FE180/E90

Download PDF

Add to inquiry

Download PDF

To inquiry

SiR/FRNC halogen-free energy cable with insulation integrity and circuit integrity, screened

These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire if circuit integrity is required.

Design

This product consists of:

  • 1
    Copper conductor, round solid (RE) resp. round stranded (RM)
  • 2
    Primary core insulation (silicone rubber)
  • 3
    Secondary core insulation (silicone rubber)
  • 4
    Inner covering (halogen-free tape and halogen free polymer compound)
  • 5
    Inner sheath (halogen-free polymer compound)
  • 6
    Concentric screen (bare copper wires), counter helix (copper tape) and halogen-free plastic tape
  • 7
    Sheath (halogen-free polymer compound, orange)

Technical Data

Standard: adapted to DIN VDE 0266
Certificate: 
  • VDE Germany
  • VDE Reg. No. 8310
Test Voltage: 4 kV / 50 Hz
Rated Voltage: 0.6/1 kV
Bending radius (min.): 12 x Ø of cable
Fire properties: 
  • EN 60332-1-2: flame retardant
  • EN 60754-2: halogen-free, non-corrosive combustion gases
  • EN IEC 60332-3-24: reduced flame propagation
  • EN 61034-2: low smoke emission
  • DIN VDE 0472-814: insulation integrity FE180
  • DIN 4102-12: circuit integrity E90
Core identification: HD 308 S2
Temperature range: 
  • Laying temperature: min. -5°C
  • Operating temperature: -50°C up to 90°C
  • Conductor temperature: max. 90°C
  • Short circuit temperature: max. 90°C
Cable image - (N)HXCH FE180/E90
+
-
Cable image - (N)HXCH FE180/E90
+
-
Cable image - (N)HXCH FE180/E90
+
-

Contact us

Are you interested in this product?

Ing. Dan Bachtík

Product supervisor

+420734366090
[email protected]

Options

Add to inquiry
Number of cores x nominal cross-section / cross-section of screen (mm²)
Number of cores x nominal cross-section / cross-section of screen (mm²)
Current rating in the air (A)
Outer diameter appr. (mm)
Total weight appr. (kg/km)
2 x 1.5 RE / 1.5
28
15.4
291
3 x 1.5 RE / 1.5
25
15.9
313
4 x 1.5 RE / 1.5
25
16.8
351
5 x 1.5 RE / 2.5
16
17.8
402
7 x 1.5 RE / 2.5
15.5
18.8
466
10 x 1.5 RE / 2.5
13
22.3
632
12 x 1.5 RE / 2.5
12.5
22.8
678
14 x 1.5 RE / 2.5
12
23.7
741
19 x 1.5 RE / 4
10.5
26.3
914
24 x 1.5 RE / 6
9.5
30.9
1244
30 x 1.5 RE / 6
9
32.4
1400
40 x 1.5 RE / 10
8
36.2
1767
2 x 2.5 RE / 2.5
37
16.1
339
3 x 2.5 RE / 2.5
33
16.7
372
4 x 2.5 RE / 2.5
33
17.7
420
5 x 2.5 RE / 2.5
22
18.8
473
7 x 2.5 RE / 2.5
20.5
19.9
561
10 x 2.5 RE / 4
17.5
24.4
795
12 x 2.5 RE / 4
16.5
25
856
14 x 2.5 RE / 4
16
25.9
940
16 x 2.5 RE / 2.5
15
26.5
1011
19 x 2.5 RE / 6
14
28.2
1169
24 x 2.5 RE / 10
12.5
33.8
1608
30 x 2.5 RE / 10
12
35.5
1822
40 x 2.5 RE / 10
11
39.7
2312
2 x 4 RE / 4
49
17.6
411
3 x 4 RE / 4
43
18.3
455
4 x 4 RE / 4
43
19.3
519
5 x 4 RE / 2.5
28
20
571
5 x 4 RE / 4
28
20.6
587
6 x 4 RE / 4
27.5
21.8
671
7 x 4 RE / 4
27
21.8
709
10 x 4 RE / 6
23
26.1
1002
12 x 4 RE / 6
22
26.8
1088
14 x 4 RE / 6
21
27.8
1201
19 x 4 RE / 10
18.5
32
1609
2 x 6 RE / 6
62
18.6
498
3 x 6 RE / 6
54
19.3
561
4 x 6 RE / 6
54
20.5
644
5 x 6 RE / 6
36
21.9
738
7 x 6 RE / 6
36
23.3
897
2 x 10 RE / 10
85
20.6
662
3 x 10 RE / 10
75
21.4
760
4 x 10 RE / 10
75
22.8
884
5 x 10 RE / 10
49
24.4
1026
2 x 16 RE / 16
113
22.4
881
2 x 16 RM / 16
113
22.9
908
3 x 16 RM / 16
100
23.9
1057
4 x 16 RE / 16
100
25
1210
4 x 16 RM / 16
100
25.6
1243
5 x 16 RM / 16
65
27.5
1456
2 x 25 RM / 16
152
26.3
1225
3 x 25 RM / 16
136
27.6
1457
4 x 25 RM / 16
136
30.7
1819
5 x 25 RM / 16
90
33.3
2163
2 x 35 RM / 16
187
28.4
1493
3 x 35 RM / 16
165
31
1893
3 x 35 RM / 35
165
32.1
2071
4 x 35 RM / 16
165
33.4
2285
5 x 35 RM / 16
109
36.5
2746
1 x 50 RM / 25
265
21
981
2 x 50 RM / 25
228
33
2073
3 x 50 RM / 25
201
34.9
2516
4 x 50 RM / 25
201
38.4
3095
5 x 50 RM / 25
133
42
3710
1 x 70 RM / 35
336
24
1307
3 x 70 RM / 35
255
40.4
3429
4 x 70 RM / 35
255
43.9
4174
5 x 70 RM / 35
180
48
5011
1 x 95 RM / 50
415
26.2
1710
3 x 95 RM / 50
314
45.4
4567
4 x 95 RM / 50
314
49.5
5589
5 x 95 RM / 50
215
54.6
6784
1 x 120 RM / 70
485
27.6
2150
3 x 120 RM / 70
364
48.5
5615
4 x 120 RM / 70
364
53.4
6937
5 x 120 RM / 70
247
58.6
8347
3 x 150 RM / 70
416
53.5
6780
4 x 150 RM / 70
416
58.6
8347
5 x 150 RM / 70
279
64.7
10124
3 x 185 RM / 95
480
59.3
8520
4 x 185 RM / 95
480
65.3
10496
3 x 240 RM / 120
565
66.4
10929
4 x 240 RM / 120
565
72.7
13438

Technical changes reserved.

All figures are therefore without guarantee.

To inquiry

Check other recommended products by SKB Group

Earthing and Short Circuiting Cables and Bare Wires

Browse products
Earthing and Short Circuiting Cables and Bare Wires
Instalation and Harmonised Cables and Wires
Low Voltage Cables 0,6/1 kV
Safety Cables with circuit integrity
Medium Voltage Cables up to 36 kV
Rubber, Silicone and PUR Cables
Commercial Vehicles and EVC Cables
Automation and Motor Supply Cables
Railway Signalling and Telecommunications Cables
Special Cables

Our Code of Conduct and its associated regulations are not seeking to „invent“ new approaches. Instead, they aim to clearly demonstrate the obligations we must fulfill nowadays.

Let's work
together

SKB

Discover

SKB Group

SKB Group logo

SKB Industrieholding GmbH

Himberger Strasse 50, 2320 Schwechat, Österreich

  • +43 1 70170-0

  • [email protected]

  • Impressum

  • Contact

All rights reserved. Copyright © 2025