SKB
Prakab
SKW
ICS
KONEKA
IKK

Menu

  • Impressum
  • Contact
  • Whistleblowing
  • Download Center
  • Products
  • Videos
SKB Group logo

Metal
Prices

Cu
SKB-Group
Validity: 12.11.2025
Cu
Quotation
€ / 100 kg:967.98
SKW
Validity: 14.11.2025
Cu
Quotation€ / 100 kg:1,006.70
Surcharge€ / 100 kg:876.70
Prakab (Czech Market)
Validity: CW 46/2025
Cu
Quotation
Kč / kg:186.69
Prakab (Slovak Market)
Validity: CW 46/2025
Cu
Quotation
€ / kg:7.72

All statements without guarantee.

Al
SKB-Group
Validity: 12.11.2025
Al
Quotation
€ / 100 kg:361.76
SKW
Validity: 14.11.2025
Al
Quotation€ / 100 kg:409.70
Surcharge€ / 100 kg:309.70
Prakab (Czech Market)
Validity: CW 46/2025
Al
Quotation
Kč / kg:55.21
Prakab (Slovak Market)
Validity: CW 46/2025
Al
Quotation
Kč / kg:55.21

All statements without guarantee.

Cables

E-AYY

Download PDF

Add to inquiry

Download PDF

To inquiry

PVC/PVC aluminium energy cables

Low Voltage Cables 0,6/1 kV

Power distribution cable for power stations, industrial facilities and switching stations as well as for local power networks. For fixed installation indoors, in cable ducts, outdoors and in water, according to the applicable erection standards, if no risk of any mechanical damage is to be expected.

Design

This product consists of:

  • 1
    Aluminium conductor, round solid (RE), sector-shaped solid (SE), round stranded (RM), resp. sector-shaped stranded (SM)
  • 2
    Core insulation (PVC)
  • 3
    Inner covering (EPDM or plastic tape)
  • 4
    Sheath (PVC black, UV-resistant)

Technical Data

Standard: ÖVE/ONORM E 8200-603 (HD 603)
Certificate: 
  • EZÚ Czech Republic
  • ÖVE Austria
Test Voltage: core/core 4 kV / 50 Hz
Rated Voltage: 0,6/1 kV
Bending radius (min.): 
  • 12 x Ø of cable (multicore)
  • 15 x Ø of cable (singlecore)
Fire properties: 
  • EN 60332-1-2: self-extinguishing
  • CPR Classification: Eca
Core identification: HD 308 S2
Temperature range: 
  • Laying temperature: min. -5°C
  • Operating temperature: -50°C up to 70°C
  • Conductor temperature: max. 70°C
  • Short circuit temperature: max. 140°C
Cable image - E-AYY
+
-
Cable image - E-AYY
+
-
Cable image - E-AYY
+
-

Contact us

Are you interested in this product?

Ing. Dan Bachtík

Product supervisor

+420734366090
[email protected]

Options

Add to inquiry
Number of cores x nominal cross-section (mm²)
Max. conductor resistance (Ω/km)
Current rating in the earth (A)
Current rating in the air (A)
Outer diameter appr. (mm)
Total weight appr. (kg/km)
1 x 25 RM
1.2
160
110
12.3
200
3 x 25 RM
1.2
102
81
22.7
715
4 x 25 RM
1.2
102
81
25.2
863
5 x 25 RM
1.2
102
81
27.6
1022
1 x 35 RM
0.868
193
135
13.3
240
3 x 35 RM
0.868
122
99
25.2
898
4 x 35 SM
0.868
122
99
24.5
801
1 x 50 RM
0.868
230
166
15
304
3 x 50 SM
0.641
144
119
25.5
813
4 x 50 SE
0.641
144
119
26.6
986
4 x 50 SM
0.641
144
119
28.3
1042
5 x 50 SM
0.641
144
119
29.6
1261
1 x 70 RM
0.443
283
210
16.5
383
3 x 70 SM
0.443
179
152
28.3
1045
4 x 70 SM
0.443
179
152
31.1
1337
5 x 70 SM
0.443
179
152
35
1682
1 x 95 RM
0.32
340
259
18.7
497
3 x 95 SM
0.32
215
186
31.7
1369
4 x 95 SM
0.32
215
186
36.6
1812
5 x 95 SM
0.32
215
186
38.8
2222
1 x 120 RM
0.253
389
302
20
584
3 x 120 SM
0.253
245
216
34.2
1633
4 x 120 SM
0.253
245
216
39.5
2163
5 x 120 SM
0.253
245
216
43.5
2664
1 x 150 RM
0.206
436
345
21.9
700
3 x 150 SM
0.206
275
246
38.2
2018
3 x 150 + 70 SM/SM
0.206 / 0,443
275
246
40.7
2306
4 x 150 SE
0.206
275
246
40.6
2466
4 x 150 SM
0.206
275
246
44.1
2623
5 x 150 SM
0.206
275
246
48.5
3320
1 x 185 RM
0.164
496
401
24.4
873
3 x 185 SM
0.164
313
285
41.8
2468
3 x 185 + 95 SM/RM
0.164 / 0,32
313
285
49.8
2980
4 x 185 SM
0.164
313
285
49.8
3317
5 x 185 SM
0.164
313
285
54.3
4103
1 x 240 RM
0.125
578
479
27.2
1095
3 x 240 SM
0.125
364
338
47.4
3214
3 x 240 + 120 SM/RM
0.125 / 0,253
364
338
55.3
3731
4 x 240 SM
0.125
364
338
55.3
4194
5 x 240 SM
0.125
364
338
64.9
5379
1 x 300 RM
0.1
654
550
29.9
1327
4 x 300 SM
0.1
419
400
62.1
5241
1 x 400 RM
0.0778
756
653
33.6
1655
1 x 500 RM
0.0605
873
772
37.1
2074
1 x 630 RM
0.0469
1011
915
42.6
2599

Technical changes reserved.

All figures are therefore without guarantee.

To inquiry

Check other recommended products by SKB Group

Low Voltage Cables 0,6/1 kV

Browse products
Low Voltage Cables 0,6/1 kV
Earthing and Short Circuiting Cables and Bare Wires
Instalation and Harmonised Cables and Wires
Safety Cables with circuit integrity
Medium Voltage Cables up to 36 kV
Rubber, Silicone and PUR Cables
Commercial Vehicles and EVC Cables
Automation and Motor Supply Cables
Railway Signalling and Telecommunications Cables
Special Cables

Our Code of Conduct and its associated regulations are not seeking to „invent“ new approaches. Instead, they aim to clearly demonstrate the obligations we must fulfill nowadays.

Let's work
together

SKB

Discover

SKB Group

SKB Group logo

SKB Industrieholding GmbH

Himberger Strasse 50, 2320 Schwechat, Österreich

  • +43 1 70170-0

  • [email protected]

  • Impressum

  • Contact

All rights reserved. Copyright © 2025